49 research outputs found

    Validation of a new portable metabolic system during an incremental running test

    Get PDF
    We tested a new portable metabolic system, the Jaeger Oxycon Mobile (OM) at a range of running speeds. Six subjects carried out, in random order, two incremental tests on a treadmill, one of them using the OM, and the other using the Jaeger Oxycon Pro (OP). There are systematic errors in the measurements of oxygen consumption (VO2) and respiratory exchange ratio (RER) with the OM. Production of CO2 (VCO2) tends to be overestimated by the OM, although the differences are not significant. Ventilation (VE) showed very similar values in both analyzers. Data of VO2 and RER were corrected with a regression equation which minimised the differences among the devices. The portable metabolic system OM makes systematic errors in measurements of VO2 and RER which can be adjusted with a regression analysis to obtain data comparable to those obtained by fixed system

    Age-related reference intervals for physical performance test outcomes relevant to male youth Middle Eastern football players

    Get PDF
    Purpose: To develop age-specific reference intervals for physical performance test outcomes relevant to male youth Middle Eastern football players. Methods: We analyzed mixed-longitudinal data (observations range: 1751–1943 assessments) from a sample of 441 male youth outfield football players (chronological age range: 11.7–18.4 y) as part of the Qatar Football Association and Aspire Academy development program over 14 competitive seasons. Semiparametric generalized additive models for location, scale, and shape estimated age-specific reference centiles for 10-m sprinting, 40-m sprinting, countermovement jump height, and maximal aerobic speed variables. Results: The estimated reference intervals indicated that the distribution of the physical performance test scores increased monotonically and nonlinearly with advancing chronological age for sprinting and countermovement jump outcome measures, reaching a plateau after 16 years common to each of these performance variables. The maximal aerobic speed median score increased substantially until ∌14.5 years, with the nonlinear trend flattening off toward relatively older chronological ages. Conclusions: We developed age-related reference intervals for physical performance test outcomes relevant to youth Qatari football players. Country-wide age-specific reference intervals can assist in the longitudinal tracking of the individual players’ progress over time against benchmark values derived from the reference population

    The percentage of mature height as a morphometric index of somatic growth: a formal scrutiny of conventional simple ratio scaling assumptions

    Get PDF
    Purpose: To assess conventional assumptions that underpin the percentage of mature height index as the simple ratio of screening height (numerator) divided by actual or predicted adult height (denominator). Methods: We examined cross-sectional data from 99 academy youth soccer players (chronological age range, 11.5 to 17.7 y) skeletally immature at the screening time and with adult height measurements available at follow-up. Results: The y-intercept value of −60 cm (95% confidence interval, −115 to −6 cm) from linear regression between screening height and adult height indicated the failure to meet the zero y-intercept assumption. The correlation coefficient between present height and adult height of .64 (95% confidence interval, .50 to .74) was not equal to the ratio of coefficient of variations between these variables (CVx/CVy = 0.46) suggesting Tanner’s special circumstance was violated. The non-zero correlation between the ratio and the denominator of .21 (95% confidence interval, .01 to .39) indicated that the percentage of mature height was biased low for players with generally shorter adult height, and vice versa. Conclusion: For the first time, we have demonstrated that the percentage of mature height is an inconsistent statistic for determining the extent of completed growth, leading to potentially biased inferences for research and applied purposes

    Non-invasive sensors for wound monitoring and therapy

    Get PDF
    Chronic wounds such as diabetic foot ulcers and venous leg ulcers affect in Europe more than 10 million people, a number that is expected to grow due to the aging of the population. Sensors can be a valid tool to improve the quality of healthcare for wound monitoring and management. The integration of sensor data within health information and decision support systems may allow the delivery of personalized treatments at decreased cost. The EU FP7 SWAN-iCare project is developing a negative-pressure device associated with non-invasive sensors capable to monitor some physiological parameters related to the wound status, such as pH, temperature and transepidermal water loss. These sensors will help to provide personalized therapies to patients and check the effectiveness of treatments remotely

    The effects of detraining and retraining periods on fat-mass and fat-free mass in elite male soccer players

    Get PDF
    The aim of the study was to examine the effects of a detraining period (DTP) (i.e., offseason) with an individually prescribed training program, and a retraining period (RTP) (i.e., pre-season) combining soccer and flywheel-based strength training on fat-free mass (FFM) and fat-mass (FM) in 10 elite professional male soccer players. The present study used a controlled repeated-measures research design to investigate the changes in FFM and FM using dual-energy X-ray absorptiometry. Whole body %FM increased (effect size (ES) = 0.87 ± 0.46) and FFM reduced after DTP (ES = -0.30 ± 0.19), returning to values comparable to the end of the previous season after RTP. At regional levels, arms, legs, and trunk %FM increased (ES = from 0.42 to 1.29) while trunk-FFM was reduced (ES=-0.40±0.26) after DTP, returning to the values observed at the end of the previous season after RTP. Legs-FFM did not change after DTP, with a substantial increase after RTP in comparison with pre-season values (ES = 0.34 ± 0.29 and 0.53 ± 0.36 for the right and left leg, respectively). Despite the small sample size of the present study, the findings indicate that elite soccer players can be allowed 2 weeks of rest during a five-week DTP, since the changes in %FM and FFM were relatively small, and FM and FFM returned to the optimal initial values for competition after the proposed RTP during the pre-season

    Cool-water immersion reduces postexercise quadriceps femoris muscle perfusion more than cold-water immersion

    Get PDF
    Purpose The muscle perfusion response to postexercise cold-water immersion (CWI) is not well understood. We examined the effects of graded postexercise CWI upon global and regional quadriceps femoris muscle perfusion using positron emission tomography and [15O]H2O. Methods Using a matched-group design, 30 healthy men performed cycle ergometer exercise at 70% VO2peak to a core body temperature of 38°C, followed by either 10 min of CWI at 8°C, 22°C, or seated rest (control). Quadriceps muscle perfusion; thigh and calf cutaneous vascular conductance; intestinal, muscle, and local skin temperatures; thermal comfort; mean arterial pressure; and heart rate were assessed at preexercise, postexercise, and after CWI. Results Global quadriceps perfusion was reduced beyond the predefined minimal clinically relevant threshold (0.75 mL per 100 g·min-1) in 22°C water versus control (difference (95% confidence interval (CI)), -2.5 (-3.9 to -1.1) mL per 100 g·min-1). Clinically relevant decreases in muscle perfusion were observed in the rectus femoris (-2.0 (-3.0 to -1.0) mL per 100 g·min-1) and vastus lateralis (-3.5 (-4.9 to -2.0) mL per 100 g·min-1) in 8°C water, and in the vastus lateralis (-3.3 (-4.8 to -1.9) mL per 100 g·min-1) in 22°C water versus control. The mean effects for vastus intermedius and vastus medialis perfusion were not clinically relevant. Clinically relevant decreases in thigh and calf cutaneous vascular conductance were observed in both cooling conditions. Conclusions The present findings revealed that less noxious CWI (22°C) promoted clinically relevant postexercise decreases in global quadriceps muscle perfusion, whereas noxious cooling (8°C) elicited no effect

    Cool-Water Immersion Reduces Post-Exercise Quadriceps Femoris Muscle Perfusion more than Cold-Water Immersion

    Get PDF
    Purpose: The muscle perfusion response to post-exercise cold water immersion (CWI) is not well understood. We examined the effects of graded post-exercise CWI upon global and regional quadriceps femoris muscle perfusion using positron emission tomography (PET) and [15O]H2O.Methods: Using a matched-group design, 30 healthy men performed cycle ergometer exercise at 70% V[Combining Dot Above]O2peak to a core body temperature of 38 °C, followed by either 10 min of CWI at 8 °C, 22 °C or seated rest (control). Quadriceps muscle perfusion, thigh and calf cutaneous vascular conductance (CVC), intestinal, muscle, and local skin temperatures, thermal comfort, mean arterial pressure, and heart rate were assessed at pre-, post-exercise and following CWI.Results: Global quadriceps perfusion was reduced beyond the pre-defined minimal clinically relevant threshold (0.75 mL·100 g·min-1) in 22 °C water versus control (difference [95% confidence interval (CI)]: -2.5 mL·100 g·min-1 [-3.9 to -1.1]). Clinically relevant decreases in muscle perfusion were observed in the rectus femoris (-2.0 mL·100 g·min-1 [-3.0 to -1.0]) and vastus lateralis (VL; -3.5 mL·100 g·min-1 [-4.9 to -2.0]) in 8 °C water, and in the vastus lateralis (-3.3 mL·100 g·min-1 [-4.8 to -1.9]) in 22 °C water versus control. The mean effects for vastus intermedius and vastus medialis perfusion were not clinically relevant. Clinically relevant decreases in thigh and calf CVC were observed in both cooling conditions.Conclusions: The present findings revealed that less noxious CWI (22 °C) promoted clinically relevant post-exercise decreases in global quadriceps muscle perfusion whereas noxious cooling (8 °C) elicited no effect.</p

    Treino de jogadores de futebol de elite de acordo com as respectivas posicoes ocupadas na equipa.

    No full text
    The aim of this study was to evaluate the actual effectiveness of an individualized training programme for soccer players according to their roles, by comparing it with an all round programme, but used the same skills training. We evaluated the second team of S. S. Lazio of Rome, monitored for two full soccer seasons. The same players served as a control group in the first season and as experimental group in the second season and were submitted to two different training programmes for an 11 month period. The two groups were homogeneous as concerns age, weight and height. Due to the fact that the physiological demands of the mid fielders and forwards are similar to those of the fullbacks and center back, respectively, the five categories were divided into three subgroups, such as: a) Goalkeepers; b) Mid fielders-Fullbacks; c) Forwards-Center backs. Control group players underwent the same physical training whereas training was differentiated according to the positional roles in the experimental group. Measurements were taken before and after the training period in order to evaluate the aerobic and anaerobic through the: Conconi's test, running tests over 30, 50, 300 and 1000 m, iso kinetic test and jump test. The mid fielders-fullbacks of the experimental group showed a significant improvement in Conconi's test and in the 1000 m run test (p&lt;0.01). A percent improvement for forwards center backs proved significant, in the sprint test (30-50 m). As regards the strength test the goalkeepers and forwards center backs showed significant improvements. In conclusion, planned according to role, developed in accordance with the real model of soccer performance and the different mechanisms of bio energetic processes, is a superior training method and can optimize the performance of all team player.Available from Fundacao para a Ciencia e a Tecnologia, Servico de Informacao e Documentacao, Av. D. Carlos I, 126, 1249-074 Lisboa, Portugal / FCT - Fundação para o CiĂȘncia e a TecnologiaSIGLEPTPortuga
    corecore